Increasing power in screening trials by testing control-arm specimens: application to multicancer detection screening

Cancer screening trials have required large sample sizes and long time-horizons to demonstrate cancer mortality reductions, the primary goal of cancer screening. We examine assumptions and potential power gains from exploiting information from testing control-arm specimens, which we call the "i...

Full description

Saved in:
Bibliographic Details
Published inJNCI : Journal of the National Cancer Institute Vol. 116; no. 8; pp. 1280 - 1287
Main Authors Katki, Hormuzd A, Prorok, Philip C, Castle, Philip E, Minasian, Lori M, Pinsky, Paul F
Format Journal Article
LanguageEnglish
Published United States Oxford University Press 01.08.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Cancer screening trials have required large sample sizes and long time-horizons to demonstrate cancer mortality reductions, the primary goal of cancer screening. We examine assumptions and potential power gains from exploiting information from testing control-arm specimens, which we call the "intended effect" (IE) analysis that we explain in detail herein. The IE analysis is particularly suited to tests that can be conducted on stored specimens in the control arm, such as stored blood for multicancer detection (MCD) tests. We simulated hypothetical MCD screening trials to compare power and sample size for the standard vs IE analysis. Under two assumptions that we detail herein, we projected the IE analysis for 3 existing screening trials (National Lung Screening Trial [NLST], Minnesota Colon Cancer Control Study [MINN-FOBT-A], and Prostate, Lung, Colorectal, Ovarian Cancer Screening Trial-colorectal component [PLCO-CRC]). Compared with the standard analysis for the 3 existing trials, the IE design could have reduced cancer-specific mortality P values 5-fold (NLST), 33-fold (MINN-FOBT-A), or 14 160-fold (PLCO-CRC) or, alternately, reduced sample size (90% power) by 26% (NLST), 48% (MINN-FOBT-A), or 59% (PLCO-CRC). For potential MCD trial designs requiring 100 000 subjects per arm to achieve 90% power for multicancer mortality for the standard analysis, the IE analysis achieves 90% power for only 37 500-50 000 per arm, depending on assumptions concerning control-arm test-positives. Testing stored specimens in the control arm of screening trials to conduct the IE analysis could substantially increase power to reduce sample size or accelerate trials and could provide particularly strong power gains for MCD tests.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Correction/Retraction-3
Hormuzd A. Katki and Paul F. Pinsky contributed equally to this work.
ISSN:1460-2105
0027-8874
1460-2105
DOI:10.1093/jnci/djae083