Synthesis of two nitrogen-doped carbon quantum dots to construct fluorescence probes for sensitive Hg2+ detection with dual signal output

The rapid and sensitive detection of heavy metal ions is of great importance in food safety and for the environment. Therefore, two novel probes, M-CQDs and P-CQDs, based on carbon quantum dots were utilized to detect Hg2+ based on fluorescence resonance energy transfer and photoinduced electron tra...

Full description

Saved in:
Bibliographic Details
Published inDalton transactions : an international journal of inorganic chemistry Vol. 52; no. 23; pp. 7982 - 7991
Main Authors Chu, Chengxiang, Zou, Chengyue, Qiu, Yue, Huo, Danqun, Deng, Yuanyi, Wang, Xianfeng, Xu, Guoren, Hou, Changjun
Format Journal Article
LanguageEnglish
Published Cambridge Royal Society of Chemistry 13.06.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The rapid and sensitive detection of heavy metal ions is of great importance in food safety and for the environment. Therefore, two novel probes, M-CQDs and P-CQDs, based on carbon quantum dots were utilized to detect Hg2+ based on fluorescence resonance energy transfer and photoinduced electron transfer mechanisms. The M-CQDs were prepared from folic acid and m-phenylenediamine (mPDA) using a hydrothermal method. Similarly, the novel P-CQDs were obtained according to the same synthetic procedure used to create M-CQDs except the mPDA was replaced with p-phenylenediamine (pPDA). Upon the addition of Hg2+ to the M-CQDs probe, the fluorescence intensity reduced significantly with a linear concentration range between 5 and 200 nM. The limit of detection (LOD) was calculated to be 2.15 nM. On the contrary, the fluorescence intensity of the P-CQDs was enhanced greatly after the addition of Hg2+. The Hg2+ detection was realized with a wide linear range from 100 to 5000 nM and the LOD was calculated to be as low as 52.5 nM. The fluorescence “quenching” and “enhancing” effect exhibited by the M-CQDs and P-CQDs, respectively, is due to the different distribution of –NH2 in the mPDA and pPDA precursors. Notably, paper-based chips modified with M/P-CQDs were established for visual Hg2+ sensing, demonstrating the possibility for real-time detection of Hg2+. Moreover, the practicality of this system was confirmed through the successful measurement of Hg2+ in tap water and river water samples.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1477-9226
1477-9234
1477-9234
DOI:10.1039/d3dt00663h