Predictors and 5-Year Clinical Outcomes of Pacemaker After TAVR: Analysis From the PARTNER 2 SAPIEN 3 Registries

Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcath...

Full description

Saved in:
Bibliographic Details
Published inJACC. Cardiovascular interventions Vol. 17; no. 11; p. 1325
Main Authors Chen, Shmuel, Dizon, Jose M, Hahn, Rebecca T, Pibarot, Philippe, George, Isaac, Zhao, Yanglu, Blanke, Philipp, Kapadia, Samir, Babaliaros, Vasilis, Szeto, Wilson Y, Makkar, Raj, Thourani, Vinod H, Webb, John G, Mack, Michael J, Leon, Martin B, Kodali, Susheel, Nazif, Tamim M
Format Journal Article
LanguageEnglish
Published United States 10.06.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:1876-7605
1876-7605
DOI:10.1016/j.jcin.2024.03.034