Diagnosis and endovascular treatment of proximal endograft instability after thoracic endografting

Four cases of proximal endostent instability after endovascular tube graft treatment of thoracic aortic disease using the TAG Gore system are reported. This potentially hazardous complication is characterized by a lack of attachment of the device to the small curvature of the aortic arch. Towering u...

Full description

Saved in:
Bibliographic Details
Published inZentralblatt für Chirurgie Vol. 132; no. 3; p. 211
Main Authors Stehr, A, Steinbauer, M, Pfister, K, Töpel, I, Herold, T, Zorger, N, Kasprzak, P M
Format Journal Article
LanguageGerman
Published Germany 01.06.2007
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:Four cases of proximal endostent instability after endovascular tube graft treatment of thoracic aortic disease using the TAG Gore system are reported. This potentially hazardous complication is characterized by a lack of attachment of the device to the small curvature of the aortic arch. Towering up against the hemodynamic forces in this area, the endograft could collapse and occlude the aorta. To identify this complication we recommend to perform an early postinterventional CT-scan with parasagittal reconstruction and an observation of the proximal endograft by fluorography. Endovascular solutions for the treatment of this complication may be either a proximal extension by another endograft or fixation of the proximal endograft by a balloon expandable Palmaz stent.
ISSN:0044-409X
DOI:10.1055/s-2007-960754