Determination of clonidine in rabbit plasma by HPLC-MS
To determine clonidine in rabbit plasma by LC-MS. The LC-MS system consisted of Waters Alliance 2790 HPLC and Micromass ZQ-4000 MS. The HPLC was performed by using XTerra C18 (150 mm x 2.1 mm ID, 5 microm). The mobile phase, consisting of acetonitrile/ammonium hydrogen carbonate solution, was mainta...
Saved in:
Published in | Yao hsüeh hsüeh pao Vol. 39; no. 5; p. 367 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | Chinese |
Published |
China
01.05.2004
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | To determine clonidine in rabbit plasma by LC-MS.
The LC-MS system consisted of Waters Alliance 2790 HPLC and Micromass ZQ-4000 MS. The HPLC was performed by using XTerra C18 (150 mm x 2.1 mm ID, 5 microm). The mobile phase, consisting of acetonitrile/ammonium hydrogen carbonate solution, was maintained to a flow-rate of 0.2 mL x min(-1) and the linear gradient elution was adopted. Mass spectrum was obtained by using electrospray ionization interface and the m/z of SIM was 230.
The average recovery was high and the method was reproducible. The calibration curve showed good linearity in the range of 1 - 80 microg x L(-1), the lowest limit of detection was 0.05 microg x L(-1). The Cmax, AUC0-t, and Tmax value of the pharmacokinetics parameter were (27 +/- 9) microg x L(-1), (5,352 +/- 1,121) microg x L(-1), (79 +/- 17) h.
The results demonstrated that the method had high sensitivity, good selectivity, accuracy and precision. It is used to determine the clonidine concentration in plasma. The transdermal patch ca |
---|---|
ISSN: | 0513-4870 |