The Re-design of a Soft X-ray Beamline for Photoemission Spectroscopy at NSRL
The monochromator of the old soft x-ray beamline for photoemission spectroscopy covering spectral range from 60 -1000 eV was designed according to Rowland Circle Monochromator for energy resolution (E/E) over 2000 with slit widths of 40 mum at NSRL. But the beamline suffers of low flux with high ene...
Saved in:
Published in | AIP conference proceedings Vol. 705; no. 1; pp. 396 - 399 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
United States
12.05.2004
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The monochromator of the old soft x-ray beamline for photoemission spectroscopy covering spectral range from 60 -1000 eV was designed according to Rowland Circle Monochromator for energy resolution (E/E) over 2000 with slit widths of 40 mum at NSRL. But the beamline suffers of low flux with high energy over 500 eV cut off and energy resolution bellow 1000 at practical flux. We reconstruct the beamline by replacement of the Kirkpatrick-Baez pre-focusing optics and the monochromator, energy resolution beyond 1000 and flux over 5X109 photons/s can be obtained with 50 mum slit widths. |
---|---|
Bibliography: | SourceType-Scholarly Journals-2 ObjectType-Feature-2 ObjectType-Conference Paper-1 content type line 23 SourceType-Conference Papers & Proceedings-1 ObjectType-Article-3 |
ISBN: | 0735401802 9780735401808 |
ISSN: | 0094-243X 1551-7616 |
DOI: | 10.1063/1.1757817 |