Initial results on energy resolution of the NEXT-White detector

One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run ta...

Full description

Saved in:
Bibliographic Details
Published inJournal of instrumentation Vol. 13; no. 10
Main Authors Renner, J, Ferrario, P, Martínez-Lema, G, Monrabal, F, Para, A, Gómez-Cadenas, J J, Adams, C, Álvarez, V, Arazi, L, Azevedo, CDR, Bailey, K, Ballester, F, Benlloch-Rodríguez, J M, Borges, FIGM, Botas, A, Cárcel, S, Carrión, J V, Cebrián, S, Conde, CAN, Díaz, J, Diesburg, M, Escada, J, Esteve, R, Felkai, R, Fernandes, AFM, Fernandes, LMP, Ferreira, AL, Freitas, EDC, Generowicz, J, Goldschmidt, A, González-Díaz, D, Guenette, R, Gutiérrez, R M, Hafidi, K, Hauptman, J, Henriques, CAO, Hernandez, AI, JA Hernando Morata, Herrero, V, Johnston, S, Jones, BJP, Kekic, M, Labarga, L, Laing, A, Lebrun, P, López-March, N, Losada, M, Mano, RDP, Martín-Albo, J, Martínez, A, McDonald, AD, Monteiro, CMB, Mora, F J, J Muñoz Vidal, Musti, M, Nebot-Guinot, M, Novella, P, DR Nygren, Palmeiro, B, Pérez, J, Psihas, F, Querol, M, Repond, J, Riordan, S, Ripoll, L, Rodríguez, J, Rogers, L, Romo-Luque, C, Santos, F P, JMF dos Santos, Simón, A, Sofka, C, Sorel, M, Stiegler, T, Toledo, J F, Torrent, J, Veloso, JFCA, Webb, R, White, J T, Yahlali, N
Format Journal Article
LanguageEnglish
Published Bristol IOP Publishing 01.10.2018
Institute of Physics (IOP)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Qββ.
Bibliography:USDOE Office of Science (SC), Nuclear Physics (NP) (SC-26)
USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
European Union (EU)
arXiv:1808.01804; FERMILAB-PUB-18-395-CD-ND
AC02-07CH11359; AC02-06CH11357; 339787-NEXT; 674896; 690575; 740055; FIS2014-53371-C04; AC02-05CH11231
European Research Council (ERC)
Spanish Ministerio de Economia y Competitividad (MINECO)
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/13/10/P10020