커튼월 건축물 파사드 리모델링을 통한 건축 환경 및 부하 분석 - 국내 오피스 빌딩 사례를 선정하여

Purpose: A curtain wall building consisting of glass has a high degree of transparency due to its material characteristics and many amount of solar energy acquisition, which is why energy consumption is high in summer. In the indoor environment, the temperature has a significant effect on the comfor...

Full description

Saved in:
Bibliographic Details
Published inKIEAE Journal Vol. 19; no. 5; pp. 75 - 86
Main Authors 이재은(Jae Eun Lee), 안광호(Kwang Ho An), 현은미(Eun Mi Hyun), 김용식(Yong Sik Kim)
Format Journal Article
LanguageKorean
Published 한국생태환경건축학회 01.10.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose: A curtain wall building consisting of glass has a high degree of transparency due to its material characteristics and many amount of solar energy acquisition, which is why energy consumption is high in summer. In the indoor environment, the temperature has a significant effect on the comfort of the occupants. Glass curtain wall buildings use a lot of air-conditioning energy because of the heat load gained from the heat storage which increases the room temperature. Initial curtain wall building were not considered, it is suggested that the cooling load be reduced by facade remodeling of installing louvers or louvers remodeling the length-increasing. It is intended to present as an architectural environmental research material for the facade remodeling of curtain wall structure suitable for the domestic environment. Methods: Theoretical contemplate of the characteristics of curtain wall building and facade remodeling was carried out. The correlation was analyzed, on the one hand related problem were deducted, and the improvement proposal for each case were architectural environmental simulated and reality building analysis. Calculate the sunshine, airflow, lighting and cooling load, and building surface temperature for the existing and improvement proposal, develop an optimal plan for the target building, the results of the analysis were aggregated and analyzed, and the search was involved out in a way to resolve. Result: Regulated of solar radiation quantity due to created length-increasing of louvers is cooling loads also decimated as average intensity of illumination values decreased. In other words, block out sunlight is an advantageous method in terms of energy reduction. However, practically that the energy and environmental standards for the facade remodeling absence a legal limit. It is need to preparation detail standards for this. KCI Citation Count: 0
Bibliography:http://dx.doi.org/10.12813/kieae.2019.19.5.075
ISSN:2288-968X
2288-9698