재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가

In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a pr...

Full description

Saved in:
Bibliographic Details
Published in한국태양에너지학회 논문집 Vol. 38; no. 6; pp. 37 - 49
Main Authors 박병용(Park Beungyong), 조진균(Cho Jinkyun), 정용대(Jeong Yongdae), 이원학(Lee Wonhak)
Format Journal Article
LanguageKorean
Published 한국태양에너지학회 2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.
Bibliography:KISTI1.1003/JNL.JAKO201810760743218
ISSN:1598-6411
2508-3562
DOI:10.7836/kses.2018.38.6.037