갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가

In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where...

Full description

Saved in:
Bibliographic Details
Published inDaehan hwan'gyeong gonghag hoeji Vol. 38; no. 7; pp. 371 - 376
Main Authors 정관조(Gwanjo Jeong), 손보영(Boyoung Son), 이인자(Inja Lee), 안치화(Chihwa Ahn), 김준일(Junil Kim), 문보람(Boram Moon), 이수원(Suwon Lee), 안재찬(Jaechan Ahn), 김복순(Bogsoon Kim), 정득모(Deukmo Chung)
Format Journal Article
LanguageKorean
Published 대한환경공학회 2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water. 본 연구에서는 에폭시 수지 갱생 옥내급수관 수돗물에 대해 비스페놀-A 실태조사를 실시하였고, 비스페놀-A가 수돗물 음용에 있어 인체에 미치는 영향을 파악하기 위해 위해성 평가를 실시하였다. 원수 중 비스페놀-A는 50~118 ng/L로 채취된 모든 시료에서 정량한계 10 ng/L 이상으로 검출되었다. 이것은 주변지역의 하수 방류수나 지천에 의한 비스페놀-A 유입에 의한 것으로 판단된다. 정수에서의 비스페놀-A는 불검출되었으며, 고도정수처리 공정에서 모두 제거된 것으로 추정되었다. 응집-침전과정과 오존 및 염소에 의해 산화되어 제거되거나 다른 산화 부산물질로 변화한 것으로 판단된다. 옥내급수관 수돗물의 경우, 에폭시 갱생공사를 실시하지 않은 수돗물 모두에서 비스페놀-A는 검출되지 않았다. 그러나 에폭시 갱생공사를 실시한 옥내급수관 수돗물에서 비스페놀-A가 불검출에서 최대 521 ng/L로 범위로 검출되었으며, 채취된 시료의 68%가 정량한계 이상으로 검출되었다. 검출된 비스페놀-A의 최대값(521 ng/L)에 대한 위해도 지수 산정 결과, 위해도 지수(HQ)는 약 0.004로 수돗물 섭취에 의한 위해판단 기준값 0.1 이하로 나타나 음용에 안전한 것을 확인하였다.
Bibliography:KISTI1.1003/JNL.JAKO201625749459081
G704-000098.2016.38.7.001
ISSN:1225-5025
2383-7810
DOI:10.4491/KSEE.2016.38.7.371