수평형 지중 열교환기의 출구온도 예측을 위한 EnergyPlus 적용 타당성에 관한 연구

Horizontal geothermal heat exchanger is affected by various factors such as pipe length, soil temperature, and outdoor environment. Simulation program is convenient for responding to various factors. The objective of this study was to determine the feasibility of using EnergyPlus to predict exit air...

Full description

Saved in:
Bibliographic Details
Published in설비공학 논문집, 28(4) Vol. 28; no. 4; pp. 131 - 136
Main Authors 황용호(Yongho Hwang), 조성우(Sungwoo Cho)
Format Journal Article
LanguageKorean
Published 대한설비공학회 2016
Subjects
Online AccessGet full text
ISSN1229-6422
2465-7611
DOI10.6110/KJACR.2016.28.4.131

Cover

More Information
Summary:Horizontal geothermal heat exchanger is affected by various factors such as pipe length, soil temperature, and outdoor environment. Simulation program is convenient for responding to various factors. The objective of this study was to determine the feasibility of using EnergyPlus to predict exit air temperature through horizontal geothermal heat exchanger in domestic. The correlation coefficient between EnergyPlus results and experimental results was 0.825. The correlation coefficient between EnergyPlus results and mathematical results was 0.722, indicating "The two values can based on Lousi on values can be Our results indicate that it is possible to use EnergyPlus to predict exit air temperature through horizontal geothermal heat exchanger.
Bibliography:KISTI1.1003/JNL.JAKO201614137727759
http://journal.auric.kr/kjacr
G704-000168.2016.28.4.001
ISSN:1229-6422
2465-7611
DOI:10.6110/KJACR.2016.28.4.131