For the safe handling of n-nonanol, this study was investigated the explosion limits of n-nonanol in the reference data. The flash points and AITs (autoignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of n-nonanol recommended 0.8 Vol...
Saved in:
Published in | 한국화재소방학회 논문지 Vol. 26; no. 2; pp. 84 - 89 |
---|---|
Main Author | |
Format | Journal Article |
Language | Korean |
Published |
한국화재소방학회
30.04.2012
|
Subjects | |
Online Access | Get full text |
ISSN | 1738-7167 2508-6804 2765-088X |
Cover
Summary: | For the safe handling of n-nonanol, this study was investigated the explosion limits of n-nonanol in the reference data. The flash points and AITs (autoignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of n-nonanol recommended 0.8 Vol.% and 6.1 Vol.%, respectively. The lower flash points of n-nonanol by using closed-cup tester were experimented $94{\sim}97^{\circ}C$. The lower flash points of n-nonanol by using open cup tester were experimented $103{\sim}104^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-nonanol. The experimental AIT of n-nonanol was $270^{\circ}C$. 노말노난올의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 노말노난올의 폭발하한계는 0.80 Vol.%, 상한계는 6.1 Vol.%를 추천하였고, 하부인화점은 밀폐계에서 $94{\sim}97^{\circ}C$와 개방식에서 $103{\sim}104^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 노말노난올의 최소자연발화온도는 $270^{\circ}C$로 측정되었다. |
---|---|
Bibliography: | KISTI1.1003/JNL.JAKO201218553920728 G704-000951.2012.26.2.003 |