사삼산화철 기반의 소립자시약(Small Particle Reagent)의 접착면 잠재지문 현출 효과에 영향을 미치는 요인
Latent fingerprint left on the adhesive sides of tapes can be easily found at a crime scene. Small Particle Reagents(SPR) based on iron oxide($Fe_3O_4$) is a technique for the detection of a latent fingerprint adhesive surface. In this study, found out that the causes affecting the quality of the fi...
Saved in:
Published in | 한국콘텐츠학회 논문지, 16(8) Vol. 16; no. 8; pp. 209 - 216 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | Korean |
Published |
한국콘텐츠학회
2016
|
Subjects | |
Online Access | Get full text |
ISSN | 1598-4877 2508-6723 |
DOI | 10.5392/JKCA.2016.16.08.209 |
Cover
Summary: | Latent fingerprint left on the adhesive sides of tapes can be easily found at a crime scene. Small Particle Reagents(SPR) based on iron oxide($Fe_3O_4$) is a technique for the detection of a latent fingerprint adhesive surface. In this study, found out that the causes affecting the quality of the fingerprints developed when used SPR based on iron oxide. To a suspension of 0.5g of iron oxide in 100ml of distilled water, 0.5ml or more surfactant were added can be developed latent fingerprints of good quality. In addition, using surfactants HLB(hydrophile-lipophile balance) value of 11~18 showed good contrast to the background and latent fingerprint. 강력범죄사건에서 발견할 수 있는 증거물인 테이프는 접착면에 지문이 쉽게 유류될 수 있다. 청 테이프에 유류된 지문을 현출하고자 사삼산화철($Fe_3O_4$)기반의 Small Particle Reagents(SPR)를 사용하여 SPR의 제조비율 및 현출에 영향을 주는 요인에 대해 연구하였다. SPR이 지문현출에 영향을 주는 요인은 제조시 첨가되는 분말의 양, 계면활성제의 양, 계면활성제의 HLB(hydrophile-lipophile balance)에 의해 영향을 받는다. 증류수 100ml를 기준으로 분말의 양은 0.5g~1.0g일 때 융선에 적절한 양이 흡착되었으며 계면활성제의 양은 0.5ml이상이면 배경에 흡착된 분말들을 잘 씻어냈다. 또한 계면활성제의 HLB가 배경과 융선과의 대조비를 높이는 중요한 요인이었으며 유류된 지문의 지질 성분을 용해시키지 않는 11~18사이의 HLB가 뛰어난 현출력을 보였다. |
---|---|
Bibliography: | KISTI1.1003/JNL.JAKO201626360540746 G704-001475.2016.16.8.061 |
ISSN: | 1598-4877 2508-6723 |
DOI: | 10.5392/JKCA.2016.16.08.209 |