강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향

This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. T...

Full description

Saved in:
Bibliographic Details
Published in시설원예·식물공장 Vol. 28; no. 1; pp. 78 - 85
Main Authors 정영균(Young Kyun Jeong), 이종구(Jong Goo Lee), 윤성욱(Sung Wook Yun), 김현태(Hyeon Tae Kim), 안은기(Enu Ki Ahn), 서재석(Jae Seok Seo), 윤용철(Yong Cheol Yoon)
Format Journal Article
LanguageKorean
Published (사)한국생물환경조절학회 2019
한국생물환경조절학회
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at 2.0~34.1oC, -6.1~22.2oC, –14.0~15.1oC and 0.4~31.5oC, -5.8~22.0oC, -14.1~16.3oC, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by 1.6oC and 2.6oC, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by –2.0oC or higher by 1.8oC than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by 0.5~7.6oC, 0.3~4.6oC and 0.5~3.9oC, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of –3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.
Bibliography:KISTI1.1003/JNL.JAKO201912261947423
ISSN:2288-0992
2288-100X