Vortex에 의한 DSI공정 중 혼합효율 향상에 관한 연구

This study carried out numerical analysis of flow field of combustion gas and sorbent to test sorbent efficiency of DSI process. To provide rapid mixing for increase utilization rate of sorbent, streamwise vorticity can be introduced into the flowing streams by other means; for example, by installin...

Full description

Saved in:
Bibliographic Details
Published in한국분무공학회지 Vol. 14; no. 1; pp. 1 - 7
Main Authors 정진도, J. D. Chung, 김장우, J. W. Kim
Format Journal Article
LanguageKorean
Published 한국분무공학회 30.03.2009
한국액체미립화학회
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This study carried out numerical analysis of flow field of combustion gas and sorbent to test sorbent efficiency of DSI process. To provide rapid mixing for increase utilization rate of sorbent, streamwise vorticity can be introduced into the flowing streams by other means; for example, by installing vortex generators immediately downstream of the wavy trailing edge. Computing results show that the degree of sorbent dispersion depends strongly on duct structure. Highest dispersion efficiency received when vortex generator was installed inside of duct. The results presented in this study a optimum condition for the development of practical DSI process.
Bibliography:Institute for Liquid Atomization and Spray Systems-Korea
KISTI1.1003/JNL.JAKO200916263465187
G704-000798.2009.14.1.005
ISSN:1226-2277
2288-9051