이동식 수소 충전 장비용 수소 밸브의 유체 온도 변화에 따른 유동 특성의 수치해석적 연구

Global efforts to reduce carbon emissions have focused attention on the development of hydrogen energy and the development of various hydrogen mobility requires mobile hydrogen charging stations. In this study, the flow characteristics of the flow control hydrogen valve for mobile hydrogen charging...

Full description

Saved in:
Bibliographic Details
Published in한국수소 및 신에너지학회 논문집 Vol. 33; no. 6; pp. 769 - 775
Main Authors 권준영(JUNYEONG KWON), 오승준(SEUNGJUN OH), 최정주(JEONGJU CHOI), 김용기(YONGKI KIM)
Format Journal Article
LanguageKorean
Published 한국수소및신에너지학회 2022
Subjects
Online AccessGet full text
ISSN1738-7264
2288-7407
DOI10.7316/KHNES.2022.33.6.769

Cover

More Information
Summary:Global efforts to reduce carbon emissions have focused attention on the development of hydrogen energy and the development of various hydrogen mobility requires mobile hydrogen charging stations. In this study, the flow characteristics of the flow control hydrogen valve for mobile hydrogen charging equipment were studied according to the temperature change of hydrogen gas. The inlet pressure was 100 MPa, the outlet pressure to 70 MPa, and temperature condition was set -40℃ to 85℃. As a result, the difference in the valve flow coefficient, which determines the capacity of the valve, showed a difference within 5% depending on the temperature.
Bibliography:KISTI1.1003/JNL.JAKO202210949977427