This study is about backwash condition and membrane fouling at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was 0.06 m3/d. The result of the test, Backwash cycle time and duration time had a significant effect on the efficiency of system and backwash...

Full description

Saved in:
Bibliographic Details
Published in한국물환경학회지, 22(1) pp. 17 - 22
Main Authors 이상협, 김승현, 문성용, 이병천, 윤종섭
Format Journal Article
LanguageKorean
Published 한국물환경학회 30.01.2006
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This study is about backwash condition and membrane fouling at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was 0.06 m3/d. The result of the test, Backwash cycle time and duration time had a significant effect on the efficiency of system and backwash. Backwash duration time was determined to be fixed in 30 seconds for the system with more than 95% recovery rate, It needed 30 minute backwash frequency. During the continuous operation, membrane fouling was analyzed by determining the filtration resistance (Ri) and cake layer resistance (Rc). At the initial stage, filtration resistance highly influenced the fouling behavior. But after 1.5 hours, cake layer resistance became more important than filtration resistant. KCI Citation Count: 2
Bibliography:G704-000646.2006.22.1.001
ISSN:2289-0971
2289-098X