우측 쇄골하 중심정맥도관 삽입 후 발생한 종격동 수종과 양측성 수흉

In many clinical settings, patients undergoing major surgery and patients with critical illness or cancer routinely receive a central venous catheter (CVC). Although several complications including hematoma formation, hemothorax, hydrothorax, chylothorax and cardiac tamponade with vascular injury ar...

Full description

Saved in:
Bibliographic Details
Published inKorean journal of anesthesiology Vol. 55; no. 1; pp. 99 - 103
Main Authors 양헌주, Hun Ju Yang, 조희경, Hee Kyung Jo, 김영주, Young Ju Kim, 조정하, Jung Ha Cho, 조춘규, Choon Kyu Cho
Format Journal Article
LanguageKorean
Published 대한마취통증의학회(구 대한마취과학회) 30.07.2008
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In many clinical settings, patients undergoing major surgery and patients with critical illness or cancer routinely receive a central venous catheter (CVC). Although several complications including hematoma formation, hemothorax, hydrothorax, chylothorax and cardiac tamponade with vascular injury are associated with the placement of CVCs, their incidence are not frequent. Especially, hydromediastinum and bilateral hydrothorax are very rare. We experienced an unusual complication of hydromediastinum and bilateral hydrothorax by left brachiocephalic vein perforation with misplacement of the catheter tip after right subclavian vein catheterization.