삽관용 후두마스크의 효용성에 관한 연구

Background : The intubating laryngeal mask airway (ILMA) was introduced recently as an effective ventilatory device and intubation guide. The following study was designed to assess not only efficacy but also safety of the ILMA. Methods : Sixty adult patients who were randomly assigned in 3 groups (G...

Full description

Saved in:
Bibliographic Details
Published inKorean journal of anesthesiology Vol. 36; no. 4; pp. 606 - 612
Main Authors 김진수, Jin Soo Kim, 정우택, Woo Taek Jung, 한찬수, Chan Soo Han, 김일호, Il Ho Kim, 김유재, Yu Jae Kim, 김천숙, Chun Sook Kim, 안기량, Ki Ryang Ahn
Format Journal Article
LanguageKorean
Published 대한마취통증의학회(구 대한마취과학회) 30.04.1999
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background : The intubating laryngeal mask airway (ILMA) was introduced recently as an effective ventilatory device and intubation guide. The following study was designed to assess not only efficacy but also safety of the ILMA. Methods : Sixty adult patients who were randomly assigned in 3 groups (Group 1, 2, 3), ASA class 1 or 2, undergoing elective surgery were induced with intravenous injection of fentanyl, thiopental sodium, vecuronium, lidocaine and inhalation of O2, N2O, enflurane. In Group 1 (n=20), the patients were intubated with Macintosh curved blade and endotracheal tube. In Group 2 (n=20), blind tracheal intubation using an ILMA was attempted. In Group 3 (n=20), we applicated the ILMA to a fiberoptic bronchoscope-aided tracheal intubation. Then we decided success rates for blind and fiberoptic-guided passage of an endotracheal tube via the ILMA. We measured systolic, diastolic arterial pressure and heart rate before administration of induction agent, 1 and 5 minutes after induction, just after intubation, 1, 2, 3 and 5 minutes after endotracheal intubation. Results : The success rates for blind (Group 2) and fiberoptic-guided (Group 3) passage of an endotracheal tube via the ILMA were 70% and 100% respectively. There were no statistically significance in the systolic, diastolic arterial pressure and heart rate when compared to value of any other groups at any time but higher in all groups when compared to preinduction value of each group just after intubation. Conclusions : Though the ILMA may be an effective intubation guide, it doesn't blunt hemodynamic changes effectively than standard laryngoscopic intubation. (Korean J Anesthesiol 1999; 36: 606∼612)
Bibliography:The Korean Society of Anesthesiologists
ISSN:2005-6419
2005-7563