Performance evaluations of fire protection panel developed for bridges
At present, the performance for fire resistance of the bridge is not generally required in its design. However, many examples damaged by a fire due to traffic accident under the bridge, doubt fire, incendiary fire and so on, have been reported. Therefore, the authors are developing the fire protecti...
Saved in:
Published in | Journal of Structural Engineering, A Vol. 58A; pp. 732 - 743 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | Japanese |
Published |
Japan Society of Civil Engineers
2012
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | At present, the performance for fire resistance of the bridge is not generally required in its design. However, many examples damaged by a fire due to traffic accident under the bridge, doubt fire, incendiary fire and so on, have been reported. Therefore, the authors are developing the fire protection panel which is composed of the Autoclaved Lightweight aerated Concrete (ALC) and Ceramic Fiber Blanket (CFB). In order to confirm the performance of the fire protection panel, the authors carried out the fire test by applying Hydrocarbon curve given by Eurocode. In this test, the thicknesses of the ALC and CFB are changed. This paper deals with the test results of the temperature and deflection distributions of the fire protection panel. |
---|---|
ISSN: | 1881-820X |
DOI: | 10.11532/structcivil.58A.732 |