Study on Static Hysteresis Characteristics of the Shear Resistant Type Panel Damper

The vibration control system is a construction method which controls the vibration of a building by using control system, in order to reduce damage of the building against external disturbance such as earthquake. When using panel damper, if it is completely fixed on structural frame, the axial force...

Full description

Saved in:
Bibliographic Details
Published inKou kouzou rombunshuu Vol. 20; no. 79; pp. 79_105 - 79_114
Main Authors HAGINOYA, Manabu, FURUKAWA, Tadatoshi, KAMIYA, Takashi, TAGUCHI, Takashi
Format Journal Article
LanguageJapanese
Published Japanese Society of Steel Construction 27.09.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The vibration control system is a construction method which controls the vibration of a building by using control system, in order to reduce damage of the building against external disturbance such as earthquake. When using panel damper, if it is completely fixed on structural frame, the axial force appears in the damper due to the damper deformation. Therefore, in this paper, the junction formation not to transfer axial force in panel damper proposed. The test is conducted for confirmation of performance of the proposed junction formation. As a result of the test, the difference in the width thickness ratio of the panel damper and junction form is clarified about the influence to give yield strength and deformation.
ISSN:1880-9928
1884-0329
DOI:10.11273/jssc.20.79_105