最大欠陥を想定した球状黒鉛鋳鉄継手の疲労限度と溶接継手との比較

In our earlier study, the authors revealed that the fatigue limit of ductile cast iron (DCI) specimens whose shapes are similar to the welded joint shapes is about three times larger than that of the welded joint specimens. However, since many defects are usually included in the DCI specimens, the f...

Full description

Saved in:
Bibliographic Details
Published in鉄と鋼 Vol. 105; no. 9; pp. 877 - 886
Main Authors 日高, 哲郎, 野田, 尚昭, 佐野, 義一, 甲斐, 信博, 藤本, 宏義
Format Journal Article
LanguageJapanese
Published 一般社団法人 日本鉄鋼協会 2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In our earlier study, the authors revealed that the fatigue limit of ductile cast iron (DCI) specimens whose shapes are similar to the welded joint shapes is about three times larger than that of the welded joint specimens. However, since many defects are usually included in the DCI specimens, the fatigue limit of DCI joints decreases with increasing the maximum defect size. In this paper, therefore, the maximum defect size is estimated by using statistics of extremes. Then, the lowest fatigue limit corresponding to the maximum defect size is estimated from the 4 parameter model and compared with the lowest fatigue limit of the welded joint. As a result, it was confirmed that the lowest fatigue limit of the DCI specimens is about twice as large as the welded joint.
ISSN:0021-1575
1883-2954
DOI:10.2355/tetsutohagane.TETSU-2019-017