A Quaternion-Based Method to IMU-to-Body Alignment for Gait Analysis

Human gait analysis based on inertial measurement units (IMUs) is still considered a challenging task. This is because the accurate capture of human body movements depends on an initial sensor-to-body calibration and alignment process. In this paper, a novel sensor-to-body alignment method based on...

Full description

Saved in:
Bibliographic Details
Published inDigital Human Modeling. Applications in Health, Safety, Ergonomics, and Risk Management Vol. 10917; pp. 217 - 231
Main Authors Narváez, Fabián, Árbito, Fernando, Proaño, Ricardo
Format Book Chapter
LanguageEnglish
Published Switzerland Springer International Publishing AG 2018
Springer International Publishing
SeriesLecture Notes in Computer Science
Subjects
Online AccessGet full text
ISBN9783319913964
3319913964
ISSN0302-9743
1611-3349
DOI10.1007/978-3-319-91397-1_19

Cover

Loading…
More Information
Summary:Human gait analysis based on inertial measurement units (IMUs) is still considered a challenging task. This is because the accurate capture of human body movements depends on an initial sensor-to-body calibration and alignment process. In this paper, a novel sensor-to-body alignment method based on sequences of quaternions is presented, which allows to accurately estimate the joint angles from the hip, knee and ankle of the lower limbs. The proposed method involves two main stages, a sensors calibration and an alignment process for the body segments, respectively. For doing that, two different sequences of rotation based on Euler angle-axis factors are developed. The first rotational sequence is used to calibrate sensor’s frame under a new general body frame by estimating the initial orientation based on its quaternion information. Then, a correction process is applied by factorizing the captured quaternions. Once the general body frame is defined, a second rotational sequence is implemented, which aligns each sensor frame to body frames, allowing to define the anatomic frames for obtaining clinical measurements of the joint angles. The proposed method was two-fold validated using both strategies, a goniometer-based measure system and a camera-based motion system, respectively. The obtained results demonstrate that the estimated joint angles are equal to the expected values and consistent with values obtained by the strategies widely used in real clinical scenarios, the goniometers and optical motion system. Therefore, the proposed method could be used in clinical applications and motion analysis of impaired persons.
ISBN:9783319913964
3319913964
ISSN:0302-9743
1611-3349
DOI:10.1007/978-3-319-91397-1_19