A Quaternion-Based Method to IMU-to-Body Alignment for Gait Analysis
Human gait analysis based on inertial measurement units (IMUs) is still considered a challenging task. This is because the accurate capture of human body movements depends on an initial sensor-to-body calibration and alignment process. In this paper, a novel sensor-to-body alignment method based on...
Saved in:
Published in | Digital Human Modeling. Applications in Health, Safety, Ergonomics, and Risk Management Vol. 10917; pp. 217 - 231 |
---|---|
Main Authors | , , |
Format | Book Chapter |
Language | English |
Published |
Switzerland
Springer International Publishing AG
2018
Springer International Publishing |
Series | Lecture Notes in Computer Science |
Subjects | |
Online Access | Get full text |
ISBN | 9783319913964 3319913964 |
ISSN | 0302-9743 1611-3349 |
DOI | 10.1007/978-3-319-91397-1_19 |
Cover
Loading…
Summary: | Human gait analysis based on inertial measurement units (IMUs) is still considered a challenging task. This is because the accurate capture of human body movements depends on an initial sensor-to-body calibration and alignment process. In this paper, a novel sensor-to-body alignment method based on sequences of quaternions is presented, which allows to accurately estimate the joint angles from the hip, knee and ankle of the lower limbs. The proposed method involves two main stages, a sensors calibration and an alignment process for the body segments, respectively. For doing that, two different sequences of rotation based on Euler angle-axis factors are developed. The first rotational sequence is used to calibrate sensor’s frame under a new general body frame by estimating the initial orientation based on its quaternion information. Then, a correction process is applied by factorizing the captured quaternions. Once the general body frame is defined, a second rotational sequence is implemented, which aligns each sensor frame to body frames, allowing to define the anatomic frames for obtaining clinical measurements of the joint angles. The proposed method was two-fold validated using both strategies, a goniometer-based measure system and a camera-based motion system, respectively. The obtained results demonstrate that the estimated joint angles are equal to the expected values and consistent with values obtained by the strategies widely used in real clinical scenarios, the goniometers and optical motion system. Therefore, the proposed method could be used in clinical applications and motion analysis of impaired persons. |
---|---|
ISBN: | 9783319913964 3319913964 |
ISSN: | 0302-9743 1611-3349 |
DOI: | 10.1007/978-3-319-91397-1_19 |