Operating Experience at Shimane Nuclear Power Plant
Shimane Nuclear Power Plant was built in the period between February, 1970 and March 29, 1974 on which this went into commercial operation. The plant has been maintained smooth operation and has entered the third annual maintenance outage. Maximum exposure of the fuel bundle has reached about 16, 00...
Saved in:
Published in | Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan Vol. 19; no. 4; pp. 233 - 236 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | Japanese |
Published |
Atomic Energy Society of Japan
30.04.1977
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Shimane Nuclear Power Plant was built in the period between February, 1970 and March 29, 1974 on which this went into commercial operation. The plant has been maintained smooth operation and has entered the third annual maintenance outage. Maximum exposure of the fuel bundle has reached about 16, 000 MWD/T. From the fuel bundle inspection and the operating data such as reactor water and off-gas activities, it has been shown that the fuel has been operated soundly. Here are the summary of the plant facility and the operating experience. |
---|---|
ISSN: | 0004-7120 2186-5256 |
DOI: | 10.3327/jaesj.19.233 |