Active Vibration Control of Frame Structures with Smart Structure Using Piezoelectric Actuator : 1st Report, Vibration Control by Control of Bending Moment of the Columns

A smart structure was tested for active vibration control of frame structures, in which bending moment of the columns was controlled by stack-type piezoelectric actuators integrated into the columns. Excitation tests were carried out for a model of a four-story building 3.7 m in height and 2000 kg i...

Full description

Saved in:
Bibliographic Details
Published inTransactions of the Japan Society of Mechanical Engineers Series C Vol. 62; no. 599; pp. 2577 - 2584
Main Authors KAMADA, Takayoshi, FUJITA, Takafumi, HATAYAMA, Takayoshi, ARIKABE, Takeo, MURAI, Nobuyoshi, AIZAWA, Satoru, TOHYAMA, Kohtaro
Format Journal Article
LanguageJapanese
Published The Japan Society of Mechanical Engineers 25.07.1996
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A smart structure was tested for active vibration control of frame structures, in which bending moment of the columns was controlled by stack-type piezoelectric actuators integrated into the columns. Excitation tests were carried out for a model of a four-story building 3.7 m in height and 2000 kg in total weight in which 32 piezoelectric actuators 25 mm×25 mm×36 mmH were used for the bending moment control. The actuators were installed in two ways: in one case eight actuators were attached to each column of the first story, and in the other case four actuators were attached to each column of the first and second stories. Two control strategies, a model-matching method and the H∞ control theory were examined for the smart structure. The tests showed that the smart structure could effectively reduce the responses of the building model, and all combinations of actuator installation method and the control strategy had almost the same performance.
ISSN:0387-5024
1884-8354