Acoustic Receiver with Co-Sensor A Canceling Method of Equi-Status Noise

This paper describes a practical method of a new type of an acoustic receiver using the co-sensor with no vibration sensor in order to decrease the influence of the equi-status noise (NMN : normal mode noise). The co-sensor is physically arranged close to the acoustic sensor as a counter measure for...

Full description

Saved in:
Bibliographic Details
Published inTransactions of the Institute of Systems, Control and Information Engineers Vol. 8; no. 4; pp. 176 - 182
Main Authors ASANO, Masahiko, OHNO, Kozou, MATSUDA, Minoru
Format Journal Article
LanguageJapanese
Published THE INSTITUTE OF SYSTEMS, CONTROL AND INFORMATION ENGINEERS (ISCIE) 15.04.1995
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper describes a practical method of a new type of an acoustic receiver using the co-sensor with no vibration sensor in order to decrease the influence of the equi-status noise (NMN : normal mode noise). The co-sensor is physically arranged close to the acoustic sensor as a counter measure for the noise circumstances. The acoustic signal is only received by the acoustic sensor and NMN is separately detected by both the acoustic sensor and the co-sensor. Then the recieved noise can be eliminated or canceled without the phase processing. From the experimental results using this method, SNR (signal noise ratio) increases around 35dB in the air 13dB under the water respectively.
ISSN:1342-5668
2185-811X
DOI:10.5687/iscie.8.176