A novel amplitude-only method of phase difference measurement between two signals by using 90° hybrid
In this study, a novel amplitude-only method to measure the phase difference between two incident signals is developed. For a 90° hybrid, it can be shown as two signals with relative phase difference ΔΦ incident to the input and isolated ports, their phase difference can be calculated from the measu...
Saved in:
Published in | Asia-Pacific Microwave Conference 2011 pp. 1806 - 1809 |
---|---|
Main Authors | , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.12.2011
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | In this study, a novel amplitude-only method to measure the phase difference between two incident signals is developed. For a 90° hybrid, it can be shown as two signals with relative phase difference ΔΦ incident to the input and isolated ports, their phase difference can be calculated from the measured power data by having two detectors connected to the direct and coupled ports. The general formulas and measurement results of a special condition are presented. |
---|---|
ISBN: | 9781457720345 1457720345 |
ISSN: | 2165-4727 2165-4743 |