A high TCR material with Si1−xGex/Si MQWs for waterborne pathogen detection

The thermistor based on Si 1-x Ge x /Si MQWs structure is one kind of biomedical materials which used in waterborne pathogen detection. Si 1-x Ge x /Si MQWs structure has high temperature coefficient of resistance (TCR), which meets the requirements for the detection of exothermic phenomenon during...

Full description

Saved in:
Bibliographic Details
Published in2012 5th International Conference on Biomedical Engineering and Informatics pp. 692 - 695
Main Authors Bo Jiang, Yan Su, Yong He, Tao Dong
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.10.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The thermistor based on Si 1-x Ge x /Si MQWs structure is one kind of biomedical materials which used in waterborne pathogen detection. Si 1-x Ge x /Si MQWs structure has high temperature coefficient of resistance (TCR), which meets the requirements for the detection of exothermic phenomenon during the reaction. In this work the theoretical model of the material has been introduced. The energy gap in valence band between barrier valence band level and Fermi level is 0.16ev and 0.21ev in the experiment and theoretical analysis respectively. The TCR values with different structure of the MQWs (25% and 30% Ge content with 10 nm wide quantum well) are -2.84% and -3.25% in the calculation respectively. The TCR test experiment has been carried out and a TCR value of -2.3 %/K was obtained after data processing.
ISBN:9781467311830
1467311839
DOI:10.1109/BMEI.2012.6513171