Proton radiation test of DC/DC converter with high voltage output
Radiation hardness of the COTS high voltage DC-DC converter was tested up to 90 krad(Si) using proton beams. Total dose effects with subsequent annealing were determined. Dependence on operating conditions and dose rate was observed. Mainly responsible parts were identified and functional failure of...
Saved in:
Published in | 2008 European Conference on Radiation and Its Effects on Components and Systems pp. 70 - 74 |
---|---|
Main Authors | , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.09.2008
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Radiation hardness of the COTS high voltage DC-DC converter was tested up to 90 krad(Si) using proton beams. Total dose effects with subsequent annealing were determined. Dependence on operating conditions and dose rate was observed. Mainly responsible parts were identified and functional failure of the device was attributed to the input current increase driven by power MOSFET. |
---|---|
ISBN: | 1457704811 9781457704819 |
ISSN: | 0379-6566 |
DOI: | 10.1109/RADECS.2008.5782686 |