Proton radiation test of DC/DC converter with high voltage output

Radiation hardness of the COTS high voltage DC-DC converter was tested up to 90 krad(Si) using proton beams. Total dose effects with subsequent annealing were determined. Dependence on operating conditions and dose rate was observed. Mainly responsible parts were identified and functional failure of...

Full description

Saved in:
Bibliographic Details
Published in2008 European Conference on Radiation and Its Effects on Components and Systems pp. 70 - 74
Main Authors Scherrer, S, Hajdas, W, Grossner, U, Schlumpf, N
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.09.2008
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Radiation hardness of the COTS high voltage DC-DC converter was tested up to 90 krad(Si) using proton beams. Total dose effects with subsequent annealing were determined. Dependence on operating conditions and dose rate was observed. Mainly responsible parts were identified and functional failure of the device was attributed to the input current increase driven by power MOSFET.