Linear generator for direct drive wave energy applications
A 50kW linear permanent magnet generator with a novel topology has been designed and built. The main significance of the generator topology is that there is no attractive force between the stator and permanent magnet translator. The magnetic force between the magnets is reacted within a self support...
Saved in:
Published in | The XIX International Conference on Electrical Machines - ICEM 2010 pp. 1 - 6 |
---|---|
Main Authors | , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.09.2010
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A 50kW linear permanent magnet generator with a novel topology has been designed and built. The main significance of the generator topology is that there is no attractive force between the stator and permanent magnet translator. The magnetic force between the magnets is reacted within a self supporting structure. The lack of magnetic forces closing the airgap and the modular nature of the generator topology makes the manufacture and assembly of the generator easier than a conventional iron-cored permanent magnet linear generator. Photos of the manufacturing process are included in this paper. The modeling techniques used to design the generator are described and a summary of the design is presented. |
---|---|
ISBN: | 9781424441747 1424441749 |
DOI: | 10.1109/ICELMACH.2010.5607840 |