PWM inverter switch open- circuit fault analysis in three phase induction motor drive using FEM

This paper examines the switch open circuit fault in a Pulse Width Modulated (PWM) Voltage Source Inverter (VSI) fed three phase induction motor (IM) using Finite Element Method (FEM). The analysis is based on the electromagnetic field parameter of the IM, when an IGBT switch in the PWM inverter leg...

Full description

Saved in:
Bibliographic Details
Published in2017 International Conference on Energy, Communication, Data Analytics and Soft Computing (ICECDS) pp. 1244 - 1248
Main Authors Kumar, N Praveen, Sreemathi, R, Chandar, K P Ragul, Vaijayanthi, V, Kumar, S Praveen
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.08.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper examines the switch open circuit fault in a Pulse Width Modulated (PWM) Voltage Source Inverter (VSI) fed three phase induction motor (IM) using Finite Element Method (FEM). The analysis is based on the electromagnetic field parameter of the IM, when an IGBT switch in the PWM inverter leg gets open circuited. The simulation is performed on 7.5kW PWM inverter fed three phase IM and several parameters like torque, speed, current, flux distribution, flux density, radial flux density are investigated under healthy & single switch open circuit faulty condition using ANSYS MAXWELL Finite Element Analysis(FEA) tool.
DOI:10.1109/ICECDS.2017.8389641