Detection and characterization of early atherosclerosis
Early stages of atherosclerosis in human subjects can be detected by lumen diameter and the pressure-strain elastic modulus. Results from non-human primate studies show that the intima thickens increasing the area enclosed by the elastic lamina. During this time the artery dilates so that the lumen...
Saved in:
Published in | The seventh Annual Symposium on Computer Applications in Medical Care, 1983 : proceedings : 23-26 October 1983 pp. 797 - 803 |
---|---|
Main Authors | , , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
1983
|
Subjects | |
Online Access | Get full text |
ISBN | 9780818605031 0818605030 |
DOI | 10.1109/SCAMC.1983.764772 |
Cover
Abstract | Early stages of atherosclerosis in human subjects can be detected by lumen diameter and the pressure-strain elastic modulus. Results from non-human primate studies show that the intima thickens increasing the area enclosed by the elastic lamina. During this time the artery dilates so that the lumen area remains essentially constant. Only after the artery reaches its elastic limit does the lumen area decrease. Accurate measurements of arterial wall thickness and lumen diameter at diastole are important to the early detection of atherosclerosis. Axial resolutions of less than 0.1mm are required to detect tissue layers within the arterial wall itself. Two approaches and results of high axial resolution, deconvolution and high axial pulse generation, meeting range resolution requirements are presented. |
---|---|
AbstractList | Early stages of atherosclerosis in human subjects can be detected by lumen diameter and the pressure-strain elastic modulus. Results from non-human primate studies show that the intima thickens increasing the area enclosed by the elastic lamina. During this time the artery dilates so that the lumen area remains essentially constant. Only after the artery reaches its elastic limit does the lumen area decrease. Accurate measurements of arterial wall thickness and lumen diameter at diastole are important to the early detection of atherosclerosis. Axial resolutions of less than 0.1mm are required to detect tissue layers within the arterial wall itself. Two approaches and results of high axial resolution, deconvolution and high axial pulse generation, meeting range resolution requirements are presented. |
Author | Bond, M.G. Barnes, R.W. Riley, W.A. Czapla, L. Birdwell, J.O. Mazzola, C.J. |
Author_xml | – sequence: 1 givenname: R.W. surname: Barnes fullname: Barnes, R.W. organization: Univ of Tenn., Knoxville, Tennessee – sequence: 2 givenname: M.G. surname: Bond fullname: Bond, M.G. – sequence: 3 givenname: W.A. surname: Riley fullname: Riley, W.A. – sequence: 4 givenname: L. surname: Czapla fullname: Czapla, L. – sequence: 5 givenname: C.J. surname: Mazzola fullname: Mazzola, C.J. – sequence: 6 givenname: J.O. surname: Birdwell fullname: Birdwell, J.O. |
BookMark | eNotj81KxDAURgMqqGMfQFd9gdbcpM3Pcqg6CiMunP1wk9wwkdpK0s349KLj5jtwFge-a3Y-zRMxdgu8BeD2_n1Yvw4tWCNbrTqtxRmrrDbcgFG85xIuWVXKB-ccrLIg4YrpB1rIL2meapxC7Q-Y0S-U0zf-yTnWhHk81rgcKM_Fj7-byg27iDgWqv65Yrunx93w3GzfNi_Detsko5fGOSuD7oKwgoTqOaCwwcYOeseV6FTnXCQrDbngMCK4KJQNqNAbIYz2csXuTtlERPuvnD4xH_enc_IHWJNHng |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/SCAMC.1983.764772 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EndPage | 803 |
ExternalDocumentID | 764772 |
GroupedDBID | 6IE 6IK 6IL AAJGR AAWTH ACGHX ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK OCL RIE RIL |
ID | FETCH-LOGICAL-i87t-bb93d74d292e26501a29d9f415b062464bbfe938ebdbafa1bf269da6ac82287c3 |
IEDL.DBID | RIE |
ISBN | 9780818605031 0818605030 |
IngestDate | Tue Aug 26 17:12:16 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i87t-bb93d74d292e26501a29d9f415b062464bbfe938ebdbafa1bf269da6ac82287c3 |
PageCount | 7 |
ParticipantIDs | ieee_primary_764772 |
PublicationCentury | 1900 |
PublicationDate | 19830000 |
PublicationDateYYYYMMDD | 1983-01-01 |
PublicationDate_xml | – year: 1983 text: 19830000 |
PublicationDecade | 1980 |
PublicationTitle | The seventh Annual Symposium on Computer Applications in Medical Care, 1983 : proceedings : 23-26 October 1983 |
PublicationTitleAbbrev | SCAMC |
PublicationYear | 1983 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0001969131 |
Score | 1.1789674 |
Snippet | Early stages of atherosclerosis in human subjects can be detected by lumen diameter and the pressure-strain elastic modulus. Results from non-human primate... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 797 |
SubjectTerms | Arteries Atherosclerosis Blood pressure Bonding Educational institutions Humans IEL Pulse generation Testing Thickness measurement |
Title | Detection and characterization of early atherosclerosis |
URI | https://ieeexplore.ieee.org/document/764772 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LSwMxEA7ag3hSa8U3OXjd7SbZZpOjVEsRKoIVeit5TKAIu2K3F3-9eSwtigcvSzaHkBeZLzPzfUHobqQ97KyIzCQrZaTkZEpzD-RK46SziomUIPvMp2_l02K06HS2IxcGAGLyGeShGGP5tjGb4CobVoE16c_bfb_LElVr506RXBJGosIjETyonHSKTtt_0gU1SSGHr-P72Tj3F26Wp0Z_PK4SbcvkKJG211GSMKSUvOebVufm65dg4z-7fYwGOxIfftmapxO0B3UfHcy6WPopqh6gjXlYNVa1xWar3JyImbhxGIL6MY4YsVn7_eW_q_UAzSeP8_E0655RyFaiajOtJbNVaamkQD0eI4pKK5033LrgtOSl1g4kE6CtVk4R7SiXVnFlPHYQlWFnqFc3NZwjXIAuLIAA44GMo1Qpf73SwlJlmJLGXaB-GP3yIwllLNPAL_-svUKHYfqTN-Ma9drPDdx4-97q27iy38jAolQ |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NS8MwGA4yQT2pc-K3PXht1yRd2hxlOqZuQ3DCbiMfb2AI7XDdxV9vPsqG4sFLaHIoDQl9nrzv-zxB6K4nLe3MMY85zbiX5MRCMkvkMmW40YIWoUB2wobv2fOsN2t8tr0WBgB88Rkk7tHn8nWl1i5U1s2datL-b3ct7Ge9INbaBlQ445hi7_GIC-Z8ThpPp00fN2lNnPLuW_9-3E_skZsm4bU_rlfx6DI4DLLtlTcldEUlH8m6lon6-mXZ-M8PP0KdrYwvet0A1DHagbKN9sZNNv0E5Q9Q-0qsMhKljtTGuzlIM6PKROD8jyPPEquV3WG2Xaw6aDp4nPaHcXORQrwo8jqWklOdZ5pwAsQyMiwI19xY6JYpIxnLpDTAaQFSS2EEloYwrgUTyrKHIlf0FLXKqoQzFKUgUw1QgLJUxhAihD1gyUIToajgypyjtpv9fBmsMuZh4hd_jt6i_eF0PJqPniYvl-jALUWIbVyhVv25hmuL9rW88av8DXwMpaE |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=The+seventh+Annual+Symposium+on+Computer+Applications+in+Medical+Care%2C+1983+%3A+proceedings+%3A+23-26+October+1983&rft.atitle=Detection+and+characterization+of+early+atherosclerosis&rft.au=Barnes%2C+R.W.&rft.au=Bond%2C+M.G.&rft.au=Riley%2C+W.A.&rft.au=Czapla%2C+L.&rft.date=1983-01-01&rft.pub=IEEE&rft.isbn=9780818605031&rft.spage=797&rft.epage=803&rft_id=info:doi/10.1109%2FSCAMC.1983.764772&rft.externalDocID=764772 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780818605031/lc.gif&client=summon&freeimage=true |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780818605031/mc.gif&client=summon&freeimage=true |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780818605031/sc.gif&client=summon&freeimage=true |