A Comparison of Roche Kinetic Interaction of Microparticles in Solution (KIMS®) Assay for Cannabinoids and GC-MS Analysis for 11-nor-9-Carboxy-Δ9-Tetrahydrocannabinol

In this study, we investigated the effectiveness of the Roche Kinetic Interaction of Microparticles in Solution (KIMS) screening assay for cannabinoid metabolites. Urine specimens (N = 1689) were collected during elimination of cannabinoids from 25 subjects with a history of marijuana use. Specimens...

Full description

Saved in:
Bibliographic Details
Published inJournal of analytical toxicology Vol. 25; no. 7; pp. 559 - 564
Main Authors Lyons, Timothy P., Okano, Catherine K., Kuhnle, Judith A., Bruins, Mark R., Darwin, William D., Moolchan, Eric T., Huestis, Marilyn A.
Format Journal Article
LanguageEnglish
Published Oxford University Press 01.10.2001
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this study, we investigated the effectiveness of the Roche Kinetic Interaction of Microparticles in Solution (KIMS) screening assay for cannabinoid metabolites. Urine specimens (N = 1689) were collected during elimination of cannabinoids from 25 subjects with a history of marijuana use. Specimens were analyzed concurrently for cannabinoid metabolites by a customized Department of Defense (DOD) cannabinoid KIMS kit (50-ng/mL cutoff) and for 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) by GC-MS (15-ng/mL cutoff). As compared to GC-MS results, the sensitivity, specificity, and efficiency of the KIMS assay were 69.7%, 99.8%, and 88.6%, respectively. Many of the false-negative results had GC-MS concentrations between 15 and 26 ng/mL (N = 151). The cannabinoid screening results for the DOD samples tested by the laboratory during the same 8-month period were also evaluated. The linear regression analyses of GC-MS results in the 15–50 ng/mL range and KIMS data resulted in regression coefficients of 0.689 for the research specimens and 0.546 for DOD specimens. The results suggest that the KIMS cannabinoid screening assay is deficient in detecting positives around the cutoff (15–25 ng/mL THC-COOH). This limitation of the KIMS cannabinoid screening method compromises the identification of true positive specimens, therefore reducing the effectiveness of the assay. The success of the DOD program is dependent on sensitive and specific screening assays; the high prevalence of false-negative cannabinoid results compromises the program's primary objective of drug deterrence.
Bibliography:The views expressed in this manuscript are those of the authors and do not reflect the official policy or position of the Department of the Army, Department of Defense, or the U.S. Government.
istex:7C92E66E78EF397BAAF3E921EC0B9BBF351D6086
ark:/67375/HXZ-WSB0G9PC-D
ISSN:0146-4760
1945-2403
DOI:10.1093/jat/25.7.559