Impact of chemiluminescent enzyme immunoassay screening for human parvovirus B19 antigen in Japanese blood donors
Background To reduce the risk of human parvovirus B19 (B19V) transmission through contaminated blood for transfusion and plasma‐derived products, the Japanese Red Cross (JRC) Blood Centers introduced B19V antigen screening by chemiluminescent enzyme immunoassay (CLEIA‐B19V) in 2008. Study Design and...
Saved in:
Published in | Transfusion (Philadelphia, Pa.) Vol. 53; no. 10pt2; pp. 2556 - 2566 |
---|---|
Main Authors | , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Blackwell Publishing Ltd
01.10.2013
Wiley Subscription Services, Inc |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background
To reduce the risk of human parvovirus B19 (B19V) transmission through contaminated blood for transfusion and plasma‐derived products, the Japanese Red Cross (JRC) Blood Centers introduced B19V antigen screening by chemiluminescent enzyme immunoassay (CLEIA‐B19V) in 2008.
Study Design and Methods
Donor samples that were positive by CLEIA‐B19V screening were tested for B19V DNA. The sensitivity of CLEIA‐B19V was tested using samples of all three genotypes and B19V DNA–positive donations. B19V DNA–positive donations and pooled plasma were quantitatively assayed for B19V DNA. B19V DNA–positive donations were phylogenetically analyzed by polymerase chain reaction direct sequencing.
Results
The sensitivity of CLEIA‐B19V was inferred to be approximately 6.3 log IU/mL with the genotype samples and 6.4 log IU/mL with B19V DNA–positive donor samples. Of 417 CLEIA‐B19V–positive samples from 1,035,560 donations in Hokkaido, Japan, 101 were positive for B19V DNA. The 198 strains of B19V DNA–positive donations in Hokkaido over the past 15 years clustered exclusively with Genotype 1. After introduction of CLEIA‐B19V, the viral load for B19V DNA in all 772 pooled plasma for fractionation from donors in nationwide Japan did not exceed 4 log IU/mL.
Conclusion
CLEIA‐B19V can detect all three genotypes of B19V (viral load >6.3 log IU/mL) and limit the viral load (<4 log IU/mL) in pooled plasma, and thus such screening has further reduced the risk of transfusion‐transmitted B19V infection. These results show that CLEIA‐B19V screening at the JRC Blood Centers can be an alternative approach to comply with recommendations regarding B19V in the United States and Europe. |
---|---|
Bibliography: | ark:/67375/WNG-9D9Q1S6J-H ArticleID:TRF3949 istex:3FF2DEBB0E1EE19DA7CF32ACBE96699DEB00F548 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Article-2 ObjectType-Feature-1 |
ISSN: | 0041-1132 1537-2995 |