Free-breathing multislice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence

Purpose To develop a novel pulse sequence for free‐breathing, multislice, native myocardial T1 mapping. Methods The slice‐interleaved T1 (STONE) sequence consists of multiple sets of single‐shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only sele...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 74; no. 1; pp. 115 - 124
Main Authors Weingärtner, Sebastian, Roujol, Sébastien, Akçakaya, Mehmet, Basha, Tamer A., Nezafat, Reza
Format Journal Article
LanguageEnglish
Published Hoboken Blackwell Publishing Ltd 01.07.2015
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To develop a novel pulse sequence for free‐breathing, multislice, native myocardial T1 mapping. Methods The slice‐interleaved T1 (STONE) sequence consists of multiple sets of single‐shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only selectively excited once after each inversion pulse to allow sampling of the unperturbed longitudinal magnetization in the adjacent slices. For respiratory motion, a prospective slice‐tracking respiratory navigator is used to decrease through‐plane motion followed by a retrospective image registration to reduce in‐plane motion. STONE T1 maps were calculated using both a two‐parameter and three‐parameter fit model. The accuracy and precision of the STONE sequence for different T1, T2, and inversion pulse efficiency were studied using numerical simulations and phantom experiments. T1 maps from 14 subjects were acquired with the STONE sequence and T1s were compared to the MOdified Look‐Locker Inversion recovery sequence (MOLLI). Results In numerical simulations and phantom experiments, the STONE sequence using a two‐parameter fit model yields more accurate T1 times compared to MOLLI, with similar high precision. The three‐parameter fit model further improves the accuracy, but with a reduced precision. The native myocardial T1 times were higher in the STONE sequence using two‐ or three‐parameter fit compared to MOLLI. The standard deviation of the T1 times was lower in the STONE T1 maps with a two‐parameter fit compared with MOLLI or a three‐parameter fit. Conclusion The STONE sequence allows accurate and precise quantification of native myocardial T1 times with the additional benefit of covering the entire ventricle. Magn Reson Med 74:115–124, 2015. © 2014 Wiley Periodicals, Inc.
Bibliography:ArticleID:MRM25387
istex:AB8FA1D4AF018B8F3BA107CF88CD76C00620E213
NIH - No. R01EB008743-01A2
ark:/67375/WNG-RX32162C-R
Samsung Electronics
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0740-3194
1522-2594
DOI:10.1002/mrm.25387