Comparative evaluation of three high-performance liquid chromatography-based Kow estimation methods for highly hydrophobic organic compounds: Polybrominated diphenyl ethers and hexabromocyclododecane

Three methods for estimating the octanol–water partition coefficient (Kow) based on its relationship with capacity factors on reversed‐phase (RP) high‐performance liquid chromatography (HPLC) columns were compared in terms of their applicability to highly hydrophobic compounds (HHCs). Methods based...

Full description

Saved in:
Bibliographic Details
Published inEnvironmental toxicology and chemistry Vol. 25; no. 8; pp. 2018 - 2027
Main Authors Hayward, Stephen J., Lei, Ying D., Wania, Frank
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Periodicals, Inc 01.08.2006
SETAC
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Three methods for estimating the octanol–water partition coefficient (Kow) based on its relationship with capacity factors on reversed‐phase (RP) high‐performance liquid chromatography (HPLC) columns were compared in terms of their applicability to highly hydrophobic compounds (HHCs). Methods based on simple isocratic elutions were found to be unsuitable, because the very high organic modifier fractions that are required to elute HHCs from RP columns challenge the basic assumption of the similarity between the octanol–water and RP–eluent systems. Compound planarity was found to exert a considerable influence on the retention of HHCs in RP columns, leading to different linear calibration curves for chlorobenzenes and chlorobiphenyls. Only an empirical exponential regression succeeded in describing the behavior of both groups of compounds during gradient elutions. In a method based on isocratic retention times at multiple temperatures, satisfactory calibration was achieved with a multivariate linear regression that included a numerical indicator of compound planarity. Considering experimental simplicity, speed, precision, and accuracy, with the latter judged by comparison with Kow values for polybrominated diphenyl ethers and polychlorinated naphthalenes as reported in the literature, a gradient elution combined with an exponential calibration curve is recommended for estimating the Kow of HHCs. To our knowledge, the first isomer‐specific Kow values for hexabromocyclododecane are reported. Bearing in mind that the influence of structural characteristics on retention is likely to increase with hydrophobicity, it is not justified to judge a HPLC‐based Kow estimation method as being suitable for HHCs because it is shown to work well for less hydrophobic substances. Whereas univariate linear regressions often may prove to be sufficient when dealing with substances having a log Kow of less than five, methods for HHCs need to account for the influence of structure on retention.
Bibliography:Supplementary MaterialsSupplementary Materials
ark:/67375/WNG-D5KQ2JBL-R
ArticleID:ETC5620250809
istex:D71CA3DEDCDF8D09C38D7BEDD44C40E0FA9B515F
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0730-7268
1552-8618
DOI:10.1897/05-675R.1