The Pocket Echocardiograph: Validation and Feasibility

Background: A new, miniaturized ultrasound device, the pocket echocardiograph (PE), is highly portable and can be carried inside a lab‐coat pocket. Studies of this device are limited and have not examined the use by novice echocardiographers. We hypothesize that a novice echocardiographer can use PE...

Full description

Saved in:
Bibliographic Details
Published inEchocardiography (Mount Kisco, N.Y.) Vol. 27; no. 7; pp. 759 - 764
Main Authors Culp, Benjamin C., Mock, Jonathan D., Chiles, Christopher D., Culp, William C.
Format Journal Article
LanguageEnglish
Published Malden, USA Blackwell Publishing Inc 01.08.2010
Subjects
Online AccessGet full text
ISSN0742-2822
1540-8175
1540-8175
DOI10.1111/j.1540-8175.2009.01125.x

Cover

Loading…
More Information
Summary:Background: A new, miniaturized ultrasound device, the pocket echocardiograph (PE), is highly portable and can be carried inside a lab‐coat pocket. Studies of this device are limited and have not examined the use by novice echocardiographers. We hypothesize that a novice echocardiographer can use PE to produce interpretable cardiac images, and that both novice and expert echocardiographers can use PE to accurately quantify ejection fraction. Methods: Unselected subjects (n = 40) in an echocardiography laboratory underwent blinded formal transthoracic echocardiography (TTE) and PE (Acuson P10, Siemens, Mountain View, CA, USA). A cardiology fellow with 2 months of echocardiography training acquired PE images. The fellow and an experienced echocardiographer interpreted the PE studies offline in a blinded fashion. To assess adequacy, studies were graded as technically adequate, limited, or inadequate. A visual estimation of ejection fraction was made. Comparisons were made to the formal reported TTE. Results: Subjects were heterogeneous, 43% male; age 64 ± 17 years, and ejection fraction 52.4%± 12.3%. All PE studies were interpretable, and the vast majority of PE and TTE images were considered technically adequate (77.5% and 85% respectively; P = 0.32). Ejection fraction showed a good correlation, bias, and limits of agreement for the fellow's interpretation (r = 0.78, −5.9%, ±16.6%) with stronger association for the experienced echocardiographer (r = 0.88, −0.8%, ±11.4%). Conclusion: Novice echocardiographers using the PE can produce adequate quality images. Both expert and novice echocardiographers can use PE to quantify ejection fraction over a broad range of patients. The device's low cost and portability may greatly expand the availability of bedside echocardiography for routine or urgent cardiovascular assessment. (Echocardiography 2010;27:759‐764)
Bibliography:istex:014D762B69070F412284BA8D1C57A50D1B9FACB4
ark:/67375/WNG-S5W9S9H0-0
ArticleID:ECHO1125
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0742-2822
1540-8175
1540-8175
DOI:10.1111/j.1540-8175.2009.01125.x