Summary A new vibration control system integrating multiple tuned mass damper (TMD) floors into building structures was recently proposed by the authors, which has been demonstrated to be highly effective in mitigating both interstory drifts and floor accelerations for low‐rise and medium‐rise build...

Full description

Saved in:
Bibliographic Details
Published inStructural control and health monitoring Vol. 22; no. 6; pp. 919 - 938
Main Authors Xiang, Ping, Nishitani, Akira
Format Journal Article
LanguageEnglish
Published Pavia Blackwell Publishing Ltd 01.06.2015
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Summary A new vibration control system integrating multiple tuned mass damper (TMD) floors into building structures was recently proposed by the authors, which has been demonstrated to be highly effective in mitigating both interstory drifts and floor accelerations for low‐rise and medium‐rise buildings. Actually, this system is attracting especially for tall buildings, which may not be suitable for base isolation because large tensile forces exert on them. This paper aims to investigate the control effect of the proposed TMD floor system for high‐rise buildings that are represented as bending‐shear type models. An optimum design criterion integrating stability maximization criterion is developed for such a multi‐degree‐of‐freedom TMD floor integrated high‐rise building system. Additionally, a multi‐objective optimization genetic algorithm Nondominated Sorting Genetic Algorithm II is employed to solve the multi‐objective optimization problem with the combination of the stability maximization criterion and H∞ or H2 criterion. Two series of numerical simulations, that is, the cases in which all the floors serve as TMDs and only a limited number of floors serve as TMDs, are conducted. The favorable performance of the proposed TMD floor system for high‐rise buildings is demonstrated by comparisons with a fixed floor building equipped with additional high‐damping devices achieving 10% first modal damping ratio under a various of seismic excitations. The TMD floor system is verified to have satisfying control effect, which can also solve the post‐earthquake long‐duration vibration problem of high‐rise buildings observed in the 2011 great Tohoku earthquake. Copyright © 2014 John Wiley & Sons, Ltd.
Bibliography:ark:/67375/WNG-GCBPWPXK-1
ArticleID:STC1725
istex:802B21F2AD4E0AEF0FA7D6EEC8F2281C001E0EC5
ISSN:1545-2255
1545-2263
DOI:10.1002/stc.1725