Quantitative T2-mapping based on multi-slice multiple gradient echo flash imaging: Retrospective correction for subject motion effects
Numerous clinical and research applications for quantitative mapping of the effective transverse relaxation time T*2 have been described. Subject motion can severely deteriorate the quality and accuracy of results. A correction method for T*2 maps acquired with multi‐slice multiple gradient echo FLA...
Saved in:
Published in | Magnetic resonance in medicine Vol. 66; no. 4; pp. 989 - 997 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Hoboken
Wiley Subscription Services, Inc., A Wiley Company
01.10.2011
Wiley Subscription Services, Inc |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Numerous clinical and research applications for quantitative mapping of the effective transverse relaxation time T*2 have been described. Subject motion can severely deteriorate the quality and accuracy of results. A correction method for T*2 maps acquired with multi‐slice multiple gradient echo FLASH imaging is presented, based on acquisition repetition with reduced spatial resolution (and consequently reduced acquisition time) and weighted averaging of both data sets, choosing weighting factors individually for each k‐space line to reduce the influence of motion. In detail, the procedure is based on the fact that motion artifacts reduce the correlation between acquired and exponentially fitted data. A target data set is constructed in image space, choosing the data yielding best correlation from the two acquired data sets. The k‐space representation of the target is subsequently approximated as linear combination of original raw data, yielding the required weighting factors. As this method only requires a single acquisition repetition with reduced spatial resolution, it can be employed on any clinical system offering a suitable sequence with export of modulus and phase images. Experimental results show that the method works well for sparse motion, but fails for strong motion affecting the same k‐space lines in both acquisitions. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc. |
---|---|
Bibliography: | Bundesministerium für Bildung und Forschung (Brain Imaging Center Frankfurt) - No. DLR 01GO0203 ark:/67375/WNG-L89W6G85-H ArticleID:MRM22878 Deutsche Forschungsgemeinschaft - No. ZA 233/1-1 istex:2EF4EF3F93F572759473222FF540A76514999BF1 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ISSN: | 0740-3194 1522-2594 1522-2594 |