1O2 determined from the measured PDT dose and 3O2 predicts long-term response to Photofrin-mediated PDT

Photodynamic therapy (PDT) that employs the photochemical interaction of light, photosensitizer and oxygen is an established modality for the treatment of cancer. However, dosimetry for PDT is becoming increasingly complex due to the heterogeneous photosensitizer uptake by the tumor, and complicated...

Full description

Saved in:
Bibliographic Details
Published inPhysics in medicine & biology Vol. 65; no. 3; p. 03LT01
Main Authors Penjweini, Rozhin, Kim, Michele M, Ong, Yi Hong, Zhu, Timothy C
Format Journal Article
LanguageEnglish
Published IOP Publishing 24.01.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Photodynamic therapy (PDT) that employs the photochemical interaction of light, photosensitizer and oxygen is an established modality for the treatment of cancer. However, dosimetry for PDT is becoming increasingly complex due to the heterogeneous photosensitizer uptake by the tumor, and complicated relationship between the tissue oxygenation ([3O2]), interstitial light distribution, photosensitizer photobleaching and PDT effect. As a result, experts argue that the failure to realize PDT's true potential is, at least partly due to the complexity of the dosimetry problem. In this study, we examine the efficacy of singlet oxygen explicit dosimetry (SOED) based on the measurements of the interstitial light fluence rate distribution, changes of [3O2] and photosensitizer concentration during Photofrin-mediated PDT to predict long-term control rates of radiation-induced fibrosarcoma tumors. We further show how variation in tissue [3O2] between animals induces variation in the treatment response for the same PDT protocol. PDT was performed with 5 mg kg−1 Photofrin (a drug-light interval of 24 h), in-air fluence rates (φair) of 50 and 75 mW cm−2 and in-air fluences from 225 to 540 J cm−2. The tumor regrowth was tracked for 90 d after the treatment and Kaplan-Meier analyses for local control rate were performed based on a tumor volume   100 mm3 for the two dosimetry quantities of PDT dose and SOED. Based on the results, SOED allowed for reduced subject variation and improved treatment evaluation as compared to the PDT dose.
Bibliography:PMB-109325.R1
Institute of Physics and Engineering in Medicine
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Correspondence-1
content type line 23
ISSN:0031-9155
1361-6560
1361-6560
DOI:10.1088/1361-6560/ab59f1