Predictive value of HbA1c for incident diabetes among subjects with impaired glucose tolerance-analysis of the Indian Diabetes Prevention Programmes

Diabet. Med. 29, 94–98 (2012) Aims  The objectives of the study were to assess the predictive value of baseline HbA1c for incident diabetes among the participants with impaired glucose tolerance in the Indian Diabetes Prevention Programmes 1 and 2. Methods  Data at baseline and at 3‐year follow‐up w...

Full description

Saved in:
Bibliographic Details
Published inDiabetic medicine Vol. 29; no. 1; pp. 94 - 98
Main Authors Ramachandran, A., Snehalatha, C., Samith Shetty, A., Nanditha, A.
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.01.2012
Blackwell
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Diabet. Med. 29, 94–98 (2012) Aims  The objectives of the study were to assess the predictive value of baseline HbA1c for incident diabetes among the participants with impaired glucose tolerance in the Indian Diabetes Prevention Programmes 1 and 2. Methods  Data at baseline and at 3‐year follow‐up were analysed in combined cohorts of the Indian Diabetes Prevention Programmes 1 and 2. Within the 3 years, 324 of the 845 participants developed diabetes (World Health Organization criteria). The predictive value of baseline HbA1c for incident diabetes was determined by logistic regression analysis. Results  Baseline HbA1c values had heterogenous distribution. The distribution was similar in isolated impaired glucose tolerance or in impaired glucose tolerance in combination with impaired fasting glucose. A progressive increase in diabetes occurred with increasing HbA1c. HbA1c showed the strongest association with incident diabetes in the multiple logistic regression analysis (odds ratio 3.548, P < 0.0001). The cut‐off HbA1c of 43 mmol/mol (6.05%) had 67% sensitivity and 60% specificity to predict future diabetes. The diagnostic sensitivity of HbA1c of ≥ 48 mmol/mol (≥ 6.5%) was only 51%, with a specificity of 87%, when compared with the oral glucose tolerance glucose values. Conclusions  Baseline HbA1c was highly predictive of future diabetes in Asian Indian subjects with impaired glucose tolerance and nearly 60% of the incidence occurred with values ≥ 42 mmol/mol (≥ 6.0). Diagnostic sensitivity of HbA1c≥ 48 mmol/mol (≥ 6.5%) for new diabetes was only 51% using the oral glucose tolerance test as the standard for comparison.
Bibliography:ark:/67375/WNG-4JWVMMNF-D
istex:D45E61C2BDDD77560AF9321394659B302DE0C5F4
ArticleID:DME3392
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0742-3071
1464-5491
1464-5491
DOI:10.1111/j.1464-5491.2011.03392.x