Study on harmonic current detection method for single-phase PV inverter

The traditional harmonic current detection algorithm is cumbersome and complex to implement in MCU. A practical single-phase ip-iq harmonic current detection algorithm is proposed in the paper. According to the characteristics of single-phase circuit instantaneous harmonic and reactive current,the a...

Full description

Saved in:
Bibliographic Details
Published in2014 China International Conference on Electricity Distribution (CICED) pp. 1621 - 1624
Main Authors Chunyang Yi, Tianfa Liao, Changwen Dong, Hongwei Zhang, Jiaxiang Xue
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.09.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The traditional harmonic current detection algorithm is cumbersome and complex to implement in MCU. A practical single-phase ip-iq harmonic current detection algorithm is proposed in the paper. According to the characteristics of single-phase circuit instantaneous harmonic and reactive current,the algorithm decompose single-phase grid current based on instantaneous reactive power theory. The new algorithm has been applied as simulation and experimental example to a single-phase PV inverter, and the results show that it is an real-time, stable, reliable detection method which can meet the requirements of the single-phase active filter.
ISSN:2161-7481
2161-749X
DOI:10.1109/CICED.2014.6991980