The impact of the CFL lamps on the power-line communications channel

A number of measurements show the results of the harmonics and conducted emissions from "Energy-Savings" Compact Fluorescent Lamps (CFL) when connected to the power-line communications channel. Different CFL's from different manufacturers were investigated. The paper covers the CENELE...

Full description

Saved in:
Bibliographic Details
Published in2013 IEEE 17th International Symposium on Power Line Communications and Its Applications pp. 225 - 229
Main Authors Emleh, A., de Beer, A. S., Ferreira, H. C., Vinck, A. J. H.
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.03.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A number of measurements show the results of the harmonics and conducted emissions from "Energy-Savings" Compact Fluorescent Lamps (CFL) when connected to the power-line communications channel. Different CFL's from different manufacturers were investigated. The paper covers the CENELEC band, as well as the broadband communications channel: 150kHz-30MHz. The obtained results show the levels of harmonics and interference that these types of lamps produce. It shows that CFL's produce interference in the 3kHz-150kHz band, but this pose no risk for PLC. Some CFL's do however produce interference in the 150kHz-30MHz band that can interfere with power-line communications.
ISBN:9781467360142
1467360147
DOI:10.1109/ISPLC.2013.6525854