Single - Triple pulse power supply for 2 KA, 20 MeV linear induction accelerator

A pulsed system for a 2 kA, 20 MeV linear induction accelerator power supply was developed. On a first stage of operation it is capable of producing a 336 kV, 2 kA, 60 ns single pulse at the accelerating inductive cells. Each cell is supplied by 8 pulse modulators based on an inductive voltage adder...

Full description

Saved in:
Bibliographic Details
Published in2017 IEEE 21st International Conference on Pulsed Power (PPC) pp. 1 - 3
Main Authors Akimov, A., Akhmetov, A., Bak, P., Baydak, A., Chernitza, A., Egorychev, M., Fedorova, L., Eliseev, A., Khrenkov, S., Kulenko, Ya, Ottmar, A., Pachkov, A., Panov, A., Pavlov, O., Petrov, D., Zhivankov, K.
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.06.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A pulsed system for a 2 kA, 20 MeV linear induction accelerator power supply was developed. On a first stage of operation it is capable of producing a 336 kV, 2 kA, 60 ns single pulse at the accelerating inductive cells. Each cell is supplied by 8 pulse modulators based on an inductive voltage adder principle. Each modulator is designed to produce pulses up to 21 kV, 10 kA with a different flattop duration of 60 or 380 ns, also it can be used in a triple pulse mode operation with a time shift between pulses which can be set from 2 to 10 μs. The modulator's single and triple pulse mode as well as the auxiliary charging and biasing systems test results are presented. Also the pseudospark switches batch testing is described.
ISSN:2158-4923
DOI:10.1109/PPC.2017.8291335