A new safe-commutation technique for AC-DC converter operation using single-phase matrix converter

This paper proposes a new safe-commutation technique for control rectifier operation using single-phase matrix converter. The aim of this paper is to develop a new safe-commutation technique for single-phase matrix converter in order to eliminate voltage spike due to an inductive load. The proposed...

Full description

Saved in:
Bibliographic Details
Published in2012 IEEE International Conference on Power and Energy (PECon) pp. 298 - 302
Main Authors Baharom, R., Hamzah, N. R., Hamzah, M. K.
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.12.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper proposes a new safe-commutation technique for control rectifier operation using single-phase matrix converter. The aim of this paper is to develop a new safe-commutation technique for single-phase matrix converter in order to eliminate voltage spike due to an inductive load. The proposed strategy was developed by consider the switches turn on time (t on ) including the rise time (t r ) and the fall time (t f ) of the actual switches to allows dead time in order to release the energy of the inductor during off time period. A computer simulation model was developed and selected results are presented to investigate and verify the proposed technique using MATLAB/Simulink (MLS).
ISBN:9781467350174
1467350176
DOI:10.1109/PECon.2012.6450226