The Photon Factory Advanced Ring (PF-AR) is a synchrotron light source dedicated to X-ray research. Although the PF-AR is usually operated at a stored beam energy of 6.5 GeV, a 5.0 GeV mode is also available for medical application. In the 6.5 GeV mode, the beam current of 60 mA in a single-bunch an...

Full description

Saved in:
Bibliographic Details
Published inProceedings of the 2005 Particle Accelerator Conference pp. 2845 - 2847
Main Authors Miyajima, T., Abe, T., Ebihara, K., Haga, K., Harada, K., Hori, Y., Ieiri, T., Isagawa, S., Kageyama, T., Kasuga, T., Katoh, T., Kawata, H., Kikuchi, M., Kobayashi, Y., Kudo, K., Mitsuhashi, T., Nagahashi, S., Nakamura, T.T., Nakanishi, H., Nogami, T., Obina, T., Ohsawa, Y., Ono, M., Ozaki, T., Sakai, H., Sakamoto, Y., Sakanaka, S., Sato, M., Satoh, M., Shioya, T., Suetake, M., Sugahara, R., Tadano, M., Takahashi, T., Takasaki, S., Tanimoto, Y., Tejima, M., Tsuchiya, K., Uchiyama, T., Ueda, A., Umemori, K., Weixing, C., Yamamoto, N., Yamamoto, S., Yoshimoto, S.
Format Conference Proceeding
LanguageEnglish
Published IEEE 2005
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The Photon Factory Advanced Ring (PF-AR) is a synchrotron light source dedicated to X-ray research. Although the PF-AR is usually operated at a stored beam energy of 6.5 GeV, a 5.0 GeV mode is also available for medical application. In the 6.5 GeV mode, the beam current of 60 mA in a single-bunch and the typical lifetime of 15 hrs at the current have been archived. Single-bunch operation for pulsed X-ray and its relatively high beam energy characterize the PF-AR. However, the high-current in single-bunch causes several problems to be solved, such as the temperature rise of some of the vacuum components, a pressure increase in the ring, and a sudden drop of beam lifetime. In order to avoid these problems, developments of new methods have been continued. In this paper, the status and the recent developments of the PF-AR are presented. It concerns: the successful operation with a two-bunch high-current operation at 5.0 GeV; the vertical beam size control for the medical application; modulating the RF acceleration phase in order to elongate the bunch length; stabilizing temperature in the ring tunnel; the study for medium emittance operation with 160 nm · rad; transferring the RF cavities in order to install a new insertion device; an innovative injection scheme using a pulsed quadrupole magnet.
ISBN:9780780388598
0780388593
ISSN:1944-4680
2152-9582
DOI:10.1109/PAC.2005.1591289