Recent Results in the Development of 170 GHz/CW Gyrotrons for ITER

Production prototype of 170 GHz/1 MW ITER gyrotron was equipped with the new quasi-optical converter to reduce the level of a stray radiation. During long-pulse test at ~500-kW power level it advanced to 120-s pulse duration. Pulse elongation was restricted within limits of the power supply. In the...

Full description

Saved in:
Bibliographic Details
Published in2006 Joint 31st International Conference on Infrared Millimeter Waves and 14th International Conference on Teraherz Electronics p. 516
Main Authors Agapova, M.V., Denisov, G.G., Ilyin, V.I., Litvak, A.G., Myasnikov, V.E., Popov, L.G., Usachev, S.V., Zapevalov, V.E., Tai, E.M.
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.09.2006
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Production prototype of 170 GHz/1 MW ITER gyrotron was equipped with the new quasi-optical converter to reduce the level of a stray radiation. During long-pulse test at ~500-kW power level it advanced to 120-s pulse duration. Pulse elongation was restricted within limits of the power supply. In the initial experiments with the gyrotron 100-ms mock-up designed for power level up to 1.5-1.7 MW, steady-state oscillations were obtained at about 1.5 MW generated power.