Time-stepping finite element analysis of starting performance of large salient-pole synchronous machines
An engineering study has been carried out to enhance the reliability of the starting system of the salient-pole synchronous machines in a pumping-generating plant. The study involves an accurate prediction of the damper bar currents and temperatures during the starting process. Time-stepping finite...
Saved in:
Published in | IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03 Vol. 3; pp. 1565 - 1570 vol.3 |
---|---|
Main Author | |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
2003
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | An engineering study has been carried out to enhance the reliability of the starting system of the salient-pole synchronous machines in a pumping-generating plant. The study involves an accurate prediction of the damper bar currents and temperatures during the starting process. Time-stepping finite element analysis for a multiple-pole model including coupled field-circuit formulation and rotor motion has been used. The predicted results are verified by experimental investigations. |
---|---|
ISBN: | 9780780378179 0780378172 |
DOI: | 10.1109/IEMDC.2003.1210659 |