Time-stepping finite element analysis of starting performance of large salient-pole synchronous machines

An engineering study has been carried out to enhance the reliability of the starting system of the salient-pole synchronous machines in a pumping-generating plant. The study involves an accurate prediction of the damper bar currents and temperatures during the starting process. Time-stepping finite...

Full description

Saved in:
Bibliographic Details
Published inIEEE International Electric Machines and Drives Conference, 2003. IEMDC'03 Vol. 3; pp. 1565 - 1570 vol.3
Main Author Kamiaker, H.C.
Format Conference Proceeding
LanguageEnglish
Published IEEE 2003
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:An engineering study has been carried out to enhance the reliability of the starting system of the salient-pole synchronous machines in a pumping-generating plant. The study involves an accurate prediction of the damper bar currents and temperatures during the starting process. Time-stepping finite element analysis for a multiple-pole model including coupled field-circuit formulation and rotor motion has been used. The predicted results are verified by experimental investigations.
ISBN:9780780378179
0780378172
DOI:10.1109/IEMDC.2003.1210659