A preliminary study on the correlation of frequency components between finger PPG and radial arterial BP waveforms
Objective: Blood pressure (BP) waveform has important meaning in the study of circulatory diseases, but its noninvasive assessment is not sufficiently user-friendly for practical applications. In the present study, we try to build up a user-friendly PPG measurement system, and study the correlation...
Saved in:
Published in | 2009 International Conference on Biomedical and Pharmaceutical Engineering pp. 1 - 4 |
---|---|
Main Authors | , , |
Format | Conference Proceeding |
Language | English Japanese |
Published |
IEEE
01.12.2009
|
Subjects | |
Online Access | Get full text |
ISBN | 1424447631 9781424447633 |
ISSN | 1947-1386 |
DOI | 10.1109/ICBPE.2009.5384104 |
Cover
Loading…
Summary: | Objective: Blood pressure (BP) waveform has important meaning in the study of circulatory diseases, but its noninvasive assessment is not sufficiently user-friendly for practical applications. In the present study, we try to build up a user-friendly PPG measurement system, and study the correlation between radial BP and finger photoplethysmography (PPG) waveforms Methods: User-friendliness of a self-made PPG measurement system was improved by applying an appropriate contacting pressure on the measured finger and adapting a hand-shape mold for the finger to put on. Finger PPG and radial-artery BP signals were then measured simultaneously and noninvasively on healthy volunteers (n=?). In frequency-domain analysis performed on each 1-minute recorded data sequence, the linear regression was applied to the calculated amplitude ratios between BP and PPG waveforms. Results: After a series of testing, the PPG measurement system was found to be user-friendly and has a good reproducibility in the frequency components within the measured PPG waveform. The BP-PPG regression of amplitude ratios were all significant (R 2 values all ¿0.72) for the first three harmonics. Conclusion: In the present study we built up a user-friendly PPG measurement system, and developed a frequency-domain analysis method to study the correlation between BP and PPG waveforms. We hope that the noninvasive PPG measurement system and the frequency-domain waveform analysis can provide an alternative and a more user-friendly method to reconstruct the radial BP waveform, and hence broaden the application of BP waveform analysis, which may bring deeper understanding for important circulatory diseases. |
---|---|
ISBN: | 1424447631 9781424447633 |
ISSN: | 1947-1386 |
DOI: | 10.1109/ICBPE.2009.5384104 |