Design of the AGS Booster ionization profile monitor

The Alternating Gradient Synchrotron (AGS) booster ionization profile monitor (IPM) must operate in a vacuum of about 3*10/sup -/0/sup 11/ Torr. The authors present details of the design of the profile monitor. The ultra-high vacuum imposes certain requirements on detector gain and restrictions on c...

Full description

Saved in:
Bibliographic Details
Published inConference Record of the 1991 IEEE Particle Accelerator Conference pp. 1189 - 1191 vol.2
Main Authors Stillman, A.N., Thern, R.E., Witkover, R.L., Van Zwienen, W.H.
Format Conference Proceeding
LanguageEnglish
Published IEEE 1991
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The Alternating Gradient Synchrotron (AGS) booster ionization profile monitor (IPM) must operate in a vacuum of about 3*10/sup -/0/sup 11/ Torr. The authors present details of the design of the profile monitor. The ultra-high vacuum imposes certain requirements on detector gain and restrictions on construction techniques. Each detector is a two-stage microchannel plate with an integral substrate containing sixty-four printed anodes. Formed electrodes provide uniform collection fields without the use of resistors, which would be unacceptable in these vacuum conditions. An ultraviolet light calibrates the detector in its permanent mounting. An extra set of electrodes performs a first order correction to the perturbations imposed by the horizontal and vertical collection electrodes.< >
ISBN:0780301358
9780780301351
DOI:10.1109/PAC.1991.164576